i have two 2 gauge power wires connected into one 2 gauge wire how should i fuse these should i put a fuse on each wire any ideas
simple992 is offline   Reply With Quote
Old 06-07-2006, 12:10 PM   #2 (permalink)
help!
--SPECIAL ED--
 
simple992's Avatar
 
Join Date: Apr 2006
Location: ontario
iTrader: (0)
Posts: 108
Images: 5
please help
simple992 is offline   Reply With Quote
Old 06-07-2006, 12:10 PM   #3 (permalink)
help!
--SPECIAL ED--
 
simple992's Avatar
 
Join Date: Apr 2006
Location: ontario
iTrader: (0)
Posts: 108
Images: 5
please help
simple992 is offline   Reply With Quote
Old 06-07-2006, 12:46 PM   #4 (permalink)
~~ VENDOR ~~
 
Smartass's Avatar
 
Join Date: Jan 2005
Location: Edmonton, Alberta
iTrader: (33)
Posts: 2,192
Images: 6
So you have one wire running from your battery to a Distribution block or Fuse block and then off into two lengths of 2 gauge?
__________________
RD Audio RD1750.1 - $500, RD Audio 1000.1 - $400 -- Great Deals!!



Sundown 100.4 Rev. D Presale! $340US Shipped!!

Smartass is offline   Reply With Quote
Old 06-07-2006, 12:47 PM   #5 (permalink)
--SPECIAL ED--
 
simple992's Avatar
 
Join Date: Apr 2006
Location: ontario
iTrader: (0)
Posts: 108
Images: 5
no i have two seperate wires from the battery connected by ring terminals into one wire at the back of the vehicle

Last edited by simple992; 06-07-2006 at 01:19 PM.
simple992 is offline   Reply With Quote
Old 06-07-2006, 01:20 PM   #6 (permalink)
--SPECIAL ED--
 
simple992's Avatar
 
Join Date: Apr 2006
Location: ontario
iTrader: (0)
Posts: 108
Images: 5
no i have
simple992 is offline   Reply With Quote
Old 06-07-2006, 01:26 PM   #7 (permalink)
Moderator
 
Killer_klown187's Avatar
 
Join Date: Dec 2005
Location: Kitchener, ontario
iTrader: (15)
Posts: 1,526
Images: 14
would that not create a problem???
__________________
I've seen many things in my time, but to achieve any of them is a different story!
Killer_klown187 is offline   Reply With Quote
Old 06-07-2006, 01:32 PM   #8 (permalink)
CCA Golden Toque
 
veeman's Avatar
 
Join Date: Nov 2004
Location: ontario, woodbridge
iTrader: (3)
Posts: 2,006
Images: 13
alright so you have 2- 2awg wires running into 1- 2awg wire. You need to fuse both of the two wires running from the battery(protects against a short which could cause a fire in either wire) as close to the battery as possible, with fuses that are rated within the current carrying capacity of the wires( a 15 foot length of 2awg(note: awg rated, not just #2) can carry about 200 amps safely). Therefore, fuses that are 200 amps or less are fine. Now you also need to fuse at the distribution point for the single wire as a short in that wire will pull more current than a single 2awg can handle(causing a fire) being supplied by 2-2awg wires. In other words, if the single 2awg shorts, it may not blow both of the 200 amp fuses before it catches on fire. Another option is; You could fuse the 2 -2awg wires at less than a 100 amps each to be safe, which will protect all the wires. Personally, I like the first option as it's a double safe system, just incase your fuse(s) don't blow early enough. Hope that helps.
__________________
2004 300M SPECIAL
Alpine CDA 9833
Alpine Pxa-h701
Alpine Rux-c701
Rockford fosgate p400-4
Rockford fosgate p4004
Hifonics BX 1205D
JBL c608 GTi
JBL p963
Infinity 2.5" center channel
Alpine type R 12"(2)
all active SQL set up with 2000 watts rms
veeman is offline   Reply With Quote
Old 06-07-2006, 01:34 PM   #9 (permalink)
--SPECIAL ED--
 
simple992's Avatar
 
Join Date: Apr 2006
Location: ontario
iTrader: (0)
Posts: 108
Images: 5
thank u kindly sir! helps lots
simple992 is offline   Reply With Quote
Old 06-07-2006, 07:08 PM   #10 (permalink)
hey veeman
--SPECIAL ED--
 
simple992's Avatar
 
Join Date: Apr 2006
Location: ontario
iTrader: (0)
Posts: 108
Images: 5
thanks went with the two fuses for now at 100 amps everything is running great and i can finally burb my sterio when the cars off before with one 4 gauge wire the amp would shut down after 2 to 3 seconds
simple992 is offline   Reply With Quote
Reply


Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 
Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On

» Advertisers












advertise here

» Recent Threads
10" spare tire enclosure advice
Last post by kin0kin
Today 08:49 PM
TF One Paper Trick *Video*
Last post by TragicMagic
Today 08:38 PM
Mr. Popularity contest CCA version
Last post by Mat-Romain
Today 08:33 PM
My New Baby!
Last post by _HeC_
Today 08:21 PM
What's your favourite Amplifier brand?
Last post by avidedtr
Today 08:19 PM
Personal Loans | Mobile Phones | Pontins | Loans | Libro infantiles

Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
SEO by vBSEO 3.2.0
Canadian Car Audio
Page generated in 0.32994 seconds with 12 queries